Single ion implantation for single donor devices using Geiger mode detectors

Physics – Condensed Matter – Mesoscale and Nanoscale Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

10 pages, 5 figures, submitted to Nanotechnology

Scientific paper

Electronic devices that are designed to use the properties of single atoms such as donors or defects have become a reality with recent demonstrations of donor spectroscopy, single photon emission sources, and magnetic imaging using defect centers in diamond. Improving single ion detector sensitivity is linked to improving control over the straggle of the ion as well as providing more flexibility in lay-out integration with the active region of the single donor device construction zone by allowing ion sensing at potentially greater distances. Using a remotely located passively gated single ion Geiger mode avalanche diode (SIGMA) detector we have demonstrated 100% detection efficiency at a distance of >75 um from the center of the collecting junction. This detection efficiency is achieved with sensitivity to ~600 or fewer electron-hole pairs produced by the implanted ion. Ion detectors with this sensitivity and integrated with a thin dielectric, for example 5 nm gate oxide, using low energy Sb implantation would have an end of range straggle of <2.5 nm. Significant reduction in false count probability is achieved by modifying the ion beam set-up to allow for cryogenic operation of the SIGMA detector. Using a detection window of 230 ns at 1 Hz, the probability of a false count was measured as 1E-1 and 1E-4 for operation temperatures of 300K and 77K, respectively. Low temperature operation and reduced false, dark, counts are critical to achieving high confidence in single ion arrival. For the device performance in this work, the confidence is calculated as a probability of >98% for counting one and only one ion for a false count probability of 1E-4 at an average ion number per gated window of 0.015.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Single ion implantation for single donor devices using Geiger mode detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Single ion implantation for single donor devices using Geiger mode detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Single ion implantation for single donor devices using Geiger mode detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-664001

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.