Limitations of X-ray reflectometry in the presence of surface contamination

Physics – Condensed Matter – Mesoscale and Nanoscale Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

13 pages, 8 figures

Scientific paper

Intentionally deposited thin films exposed to atmosphere often develop unintentionally deposited few monolayer films of surface contamination. This contamination arises from the diverse population of volatile organics and inorganics in the atmosphere. Such surface contamination can affect the uncertainties in determination of thickness, roughness and density of thin film structures by X-Ray Reflectometry (XRR). Here we study the effect of a 0.5 nm carbon surface contamination layer on thickness determination for a 20 nm titanium nitride thin film on silicon. Uncertainties calculated using Markov-Chain Monte Carlo Bayesian statistical methods from simulated data of clean and contaminated TiN thin films are compared at varying degrees of data quality to study (1) whether synchrotron sources cope better with contamination than laboratory sources and (2) whether cleaning off the surface of thin films prior to XRR measurement is necessary. We show that, surprisingly, contributions to uncertainty from surface contamination can dominate uncertainty estimates, leading to minimal advantages in using synchrotron- over laboratory-intensity data. Further, even prior knowledge of the exact nature of the surface contamination does not significantly reduce the contamination's contribution to the uncertainty in the TiN layer thickness. We conclude, then, that effective and standardized cleaning protocols are necessary to achieve high levels of accuracy in XRR measurement.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Limitations of X-ray reflectometry in the presence of surface contamination does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Limitations of X-ray reflectometry in the presence of surface contamination, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Limitations of X-ray reflectometry in the presence of surface contamination will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-145239

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.