Reflectance calibrations of AXAF witness mirrors using synchrotron radiation: 2 to 12 keV

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

For the past six years, a high-accuracy reflectance calibration system has been under development at the National Synchrotron Light Source at Brookhaven National Laboratory. The system utilizes Los Alamos National Laboratory's Beamlines X8A and X8C. Its purpose is to calibrate the reflection efficiencies of witness coupons associated with the coating of the eight mirror elements composing the High Resolution Mirror Assembly for NASA's Advanced X-ray Astrophysics Facility (AXAF). During the past year, measurements of reflectances of numerous iridium- coated witness flat mirrors have been obtained to a relative statistical precision of 0.4 percent, and an overall repeatability within 0.8 percent in the overlapping energy regions. The coating processes are strikingly repeatable, with reflectances in the 5-10 keV range for off-end witness flats nearly always being within 1 percent of one another, excluding interference fringes. The comparison reflectances between flats obtained from qualification coating runs and production runs of the Wolter Type I mirror elements are in turn nearly equal, indicating that the qualification run witness flats provide a good representation of the flight optics. Results will produce a calibration of AXAF with extremely good energy detail over the 2-12 keV range, which includes details of the M-absorption edge region for Ir. Development of the program to cover 0.05-2 keV continues.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Reflectance calibrations of AXAF witness mirrors using synchrotron radiation: 2 to 12 keV does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Reflectance calibrations of AXAF witness mirrors using synchrotron radiation: 2 to 12 keV, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Reflectance calibrations of AXAF witness mirrors using synchrotron radiation: 2 to 12 keV will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1384159

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.