Physics
Scientific paper
Apr 2007
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2007wfc..rept...11b&link_type=abstract
Instrument Science Report WFC3 2007-11, 6 pages
Physics
Hubble Space Telescope, Hst, Space Telescope Science Institute, Wide Field Camera 3, Wfc3, Ambient 2 Test, Uvis
Scientific paper
The integrated WFC3 instrument recently underwent testing under ambient conditions at Goddard Space Flight Center (GSFC); the UVIS-2 detector was in place, operated at -54 C. One of the tests performed was the relative gain procedure (UV03S01A); analysis of the data show that the gains, assuming a nominal gain of 1.5 e-/DN for the gain 1.5 setting, are on average 1.03, 2.10, and 4.28 e-/DN with errors ~0.01 e-/DN. A check of the absolute gain at the nominal 1.5 setting was performed using a set of flatfield pairs; gains were measured at 1.58, 1.55, 1.65, and 1.61 e-/DN, with errors ~0.01 e-/DN, for quadrants A,B,C, and D.
No associations
LandOfFree
WFC3 Ambient-2 Testing: UVIS Gain Results does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with WFC3 Ambient-2 Testing: UVIS Gain Results, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and WFC3 Ambient-2 Testing: UVIS Gain Results will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1361534