Physics
Scientific paper
Apr 2007
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2007wfc..rept...10h&link_type=abstract
Instrument Science Report WFC3 2007-10, 9 pages
Physics
Hubble Space Telescope, Hst, Space Telescope Science Institute, Wide Field Camera 3, Wfc3, Uvis
Scientific paper
Ground testing of WFC3 under ambient conditions during April of 2007 was performed in order to prepare for upcoming thermal vacuum testing. As a part of this ambient testing, the dark current rate of the spare UVIS package (UVIS build 2) was measured while the CCD was operating at a temperature of -54oC. This temperature is significantly higher than the nominal operating temperature of -83oC, leading to a higher overall dark current rate, as well as a larger population in the high dark current tail of the distribution. Measured dark current values at the peak of the distributions corresponding to the 4 amplifiers were 9.0 ? 13.9 e-/pix/hour.
No associations
LandOfFree
WFC3 Ambient Testing: UVIS Dark Current Rate does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with WFC3 Ambient Testing: UVIS Dark Current Rate, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and WFC3 Ambient Testing: UVIS Dark Current Rate will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1361533