Signature of a crossed Andreev reflection effect (CARE) in the magnetic response of YBCO junctions with the itinerant ferromagnet SrRuO_3

Physics – Condensed Matter – Superconductivity

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

6 figures

Scientific paper

10.1103/PhysRevB.72.184515

Magnetic properties of SFS and SF ramp-type junctions with $YBa_2Cu_3O_{7-\delta}$ (YBCO) electrodes (S), and the itinerant ferromagnet $SrRuO_3$ (SRO - F), were investigated. We looked for a crossed Andreev reflection effect (CARE) in which an electron from one magnetic domain in F is Andreev reflected as a hole into an adjacent, oppositely polarized, domain while a pair is transmitted into S. CARE is possible in SRO since the width of its domain walls is of the order of the YBCO coherence length (2-3 nm). Our junctions behave as typical magnetic tunneling junctions, as the conductance spectra were always asymmetric, and a few showed bound state peaks at finite bias that shifted with field according to the classical Tedrow and Meservey theory. In many of our SFS junctions with a barrier thickness of 10-20 nm, a prominent zero bias conductance peak (ZBCP) has been observed. This peak was found to decrease \textit{linearly} with magnetic field, as expected for Andreev and CARE scattering. In contrast, in SF junctions, the observed ZBCP was found to decrease versus field almost \textit{exponentially}, in agreement with the Anderson-Appelbaum theory of scattering by magnetic states in F. Thus, transport in our SFS and SF junctions depends strongly on the size of the F layer. We also found that in both cases, the ZBCP height at zero field decreased with increasing magnetic order of the domains in F, in agreement with the CARE mechanism.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Signature of a crossed Andreev reflection effect (CARE) in the magnetic response of YBCO junctions with the itinerant ferromagnet SrRuO_3 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Signature of a crossed Andreev reflection effect (CARE) in the magnetic response of YBCO junctions with the itinerant ferromagnet SrRuO_3, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Signature of a crossed Andreev reflection effect (CARE) in the magnetic response of YBCO junctions with the itinerant ferromagnet SrRuO_3 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-116133

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.