Physics
Scientific paper
Jul 2010
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2010spie.7734e.132j&link_type=abstract
Optical and Infrared Interferometry II. Edited by Danchi, William C.; Delplancke, Françoise; Rajagopal, Jayadev K. Proceeding
Physics
Scientific paper
The MROI fringe tracking beam combiner will be the first fringe instrument for the interferometer. It was designed to utilize the array geometry and maximize sensitivity to drive the interferometer for faint source imaging. Two primary concerns have driven the design philosophy: 1) maintaining high throughput and visibilities in broadband polarized light, and 2) mechanical stability. The first concern was addressed through tight fabrication tolerances of the combiner substrates, and custom coatings. In order to optimize mechanical stability, a unique modular design approach was taken that minimizes the number of internal adjustments. This paper reports initial laboratory fringe and stability measurements.
Buscher David
Creech-Eakman Michelle
Haniff Chris
Jurgenson Colby
Klinglesmith Dan
No associations
LandOfFree
The MROI fringe tracker: first fringe experiment does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with The MROI fringe tracker: first fringe experiment, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The MROI fringe tracker: first fringe experiment will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1378786