The optical components of the Swift Gamma Ray Burst Explorer X-ray Telescope (XRT), consisting of the JET-X spare flight mirror and a charge coupled device of the type used in the EPIC program, were used in a re-calibration study carried out at the Panter facility, which is part of the Max Plank Institute for Extraterrestrial Physics. The objective of this study was to check the focal length and the off axis performance of the mirrors and to show that the half energy width (HEW) of the on-axis point spread function (PSF) was of the order of 16arcsec at 1.5keV (Nucl. Instr. and Meth. A 488 (2002) 543; SPIE 4140 (2000) 64) and that a centroiding accuracy better that 1arcsec could be achieved within the 4arcmin sampling area designated by the Burst Alert Telescope (Nucl. Instr. and Meth. A 488 (2002) 543). The centroiding accuracy of the Swift XRT's optical components was tested as a function of distance from the focus and off axis position of the PSF (Nucl. Instr. and Meth. A 488 (2002) 543). The presence of background events in the image frame introduced errors in the centroiding process, making the choice of centroiding algorithm important (Nucl. Instr. and Meth. A 488 (2002) 543). Since the objective of Swift is to rapidly investigate the X-ray afterglows of Gamma Ray Bursts the possibility of detecting a bright source with intensity greater than 25 Crab could not be excluded and therefore the impact of a saturated PSF core on the centroiding accuracy was investigated by experimental methods.
Abbey Anthony F.
Ambrosi Richard M.
Cheruvu Chaitanya
Hill James
Hutchinson Ian B.
No associations
LandOfFree
The impact of the in-orbit background and the X-ray source intensity on the centroiding accuracy of the Swift X-ray telescope does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with The impact of the in-orbit background and the X-ray source intensity on the centroiding accuracy of the Swift X-ray telescope, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The impact of the in-orbit background and the X-ray source intensity on the centroiding accuracy of the Swift X-ray telescope will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1192101