The design and alignment of the DECam lenses and modelling of the static shear pattern and its impact on weak lensing measurements

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The Dark Energy Survey (DES) will produce high quality images covering over 5000 square degrees of the sky, with precise photometric redshifts between z = 0.2 to z = 1.3, using g, r, i, z and Y filters. The Dark Energy Camera (DECam), under construction for this survey, consists of wide field corrector optics and a CCD detector array that will give a 2.2 square degree field of view. It will be placed at the prime focus of the Blanco 4-meter telescope at the Cerro Tololo Inter-American Observatory in Chile. The Optical Science Laboratory (OSL) at University College London (UCL) is undertaking the alignment of the five lenses in the imaging system. These lenses range in diameter from 0.60 - 0.98 meters. The lenses must be held within tight tolerance limits in order to meet the DES science requirements. The tolerances are especially driven by the accuracy in the measurement of the weak lensing signal. This paper details the design for the cells that will hold the lenses and the alignment procedure for the mounting of the lenses and cells. Also presented is the expected static shear distortion pattern that will be generated and the impact of this pattern on the weak lensing signal measurement.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The design and alignment of the DECam lenses and modelling of the static shear pattern and its impact on weak lensing measurements does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The design and alignment of the DECam lenses and modelling of the static shear pattern and its impact on weak lensing measurements, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The design and alignment of the DECam lenses and modelling of the static shear pattern and its impact on weak lensing measurements will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1301735

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.