Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Re-Revised version after 2nd peer review process

Scientific paper

10.1088/1748-0221/6/11/P11005

The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to perform X-ray Photon Correlation Spectroscopy (XPCS) experiments on sub-microsecond timescales with non-ergodic systems. A case study for the Adaptive Gain Integrating Pixel Detector (AGIPD) at the European XFEL employing the intensity autocorrelation technique was performed using the detector simulation tool HORUS. As optimum results from XPCS experiments are obtained when the pixel size approximates the (small) speckle size, the presented study compares the AGIPD (pixel size of (200 $\upmu$m)$^2$) to a possible apertured version of the detector and to a hypothetical system with (100 $\upmu$m)$^2$ pixel size and investigates the influence of intensity fluctuations and incoherent noise on the quality of the acquired data. The intuitive conclusion that aperturing is not beneficial as data is 'thrown away' was proven to be correct for low intensities. For intensities larger than approximately 1 photon per (100 $\upmu$m)$^2$ aperturing was found to be beneficial, as charge sharing effects were excluded by it. It was shown that for the investigated case (100 $\upmu$m)$^2$ pixels produced significantly better results than (200 $\upmu$m)$^2$ pixels when the average intensity exceeded approximately 0.05 photons per (100 $\upmu$m)$^2$. Although the systems were quite different in design they varied in the signal to noise ratio only by a factor of 2-3, and even less in the relative error of the extracted correlation constants. However the dependence on intensity showed distinctively different features for the different systems.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-301642

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.