Physics
Scientific paper
Jun 2005
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2005spie.5834...34f&link_type=abstract
18th International Conference on Photoelectronics and Night Vision Devices. Edited by Filachov, Anatoly M.; Ponomarenko, Vladim
Physics
Scientific paper
The results of development researches and tests of the 4x288 focal plane array (FPA) for a spectral range 8-12 microns are given. The cooled photoreception module of the FPA represents hybrid assembly of a matrix photosensitive element based on liquid phase epitaxy (LPE) mercury-cadmium-telluride (MCT) photodiodes and cooled silicon readout integrated circuit (ROIC). Connection of the MCT and ROIC is carried out by means of In bumps. Cooled silicon readout circuits have been made by n-MOS technology with no TDI stages at focal plane. For 11.5 μm cutoff wavelength detectivity is higher then 1x1011 cmW-1Hz1/2 for 4x288 FPA with four TDI elements.
Akimov V. M.
Boltar' K. O.
Burlakov I. D.
Filachev A. M.
Klimanov E. A.
No associations
LandOfFree
Results of development and research of the LWIR 4x288 FPA based on MCT photodiodes does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Results of development and research of the LWIR 4x288 FPA based on MCT photodiodes, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Results of development and research of the LWIR 4x288 FPA based on MCT photodiodes will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1166536