Physics
Scientific paper
Nov 1968
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1968sci...162.1020s&link_type=abstract
Science, Volume 162, Issue 3857, pp. 1020-1023
Physics
1
Scientific paper
Data on pulmonary gas exchange were collected in breathhold dives to 90 feet in a tank and in open-sea breathhold dives to depths of 217.5 and 225 feet. Thoracic blood volume displacements were measured at depths of 25, 50, 90, and 130 feet, by use of the impedance plethysmograph. The open-sea dives were carried out with an average speed of descent of 3.95 feet per second and an average rate of ascent of 3.50 feet per second. End-dive alveolar oxygen tensions did not fall below 36 millimeters of mercury, while alveolar carbon dioxide tension did not rise above 40 millimeters of mercury except in one case. These findings indicate that for diver Croft, who has unusual lung capacity, neither hypoxia nor hypercapnia determined the depth limits under those conditions. At depths of 90 and 130 feet blood was forced into the thorax, amounting to 1047 and 850 milliliters respectively.
Allison Robert D.
Carey Charles R.
Dougherty James H. Jr.
Parker Donald
Schaefer Karl E.
No associations
LandOfFree
Pulmonary and Circulatory Adjustments Determining the Limits of Depths in Breathhold Diving does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Pulmonary and Circulatory Adjustments Determining the Limits of Depths in Breathhold Diving, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Pulmonary and Circulatory Adjustments Determining the Limits of Depths in Breathhold Diving will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1261781