Physics
Scientific paper
Aug 2002
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2002nimpa.488..543a&link_type=abstract
Nuclear Instruments and Methods in Physics Research Section A, Volume 488, Issue 3, p. 543-554.
Physics
1
Scientific paper
The optical components of the Swift X-ray telescope (XRT) are already developed items. They are the flight spare X-ray mirror from the JET-X/Spectrum-X program and an MOS CCD (CCD22) of the type currently operating in orbit as part of the EPIC focal plane camera on XMM-Newton (SPIE 4140 (2000) 64). The JET-X mirrors were first calibrated at the Max Plank Institute for Extraterrestrial Physics' (MPE) Panter facility, Garching, Germany in 1996 (SPIE 2805 (1996) 56; SPIE 3114 (1997) 392). Half-energy widths of 16arcsec at 1.5keV were confirmed for the two flight mirrors and the flight spare. The calibration of the flight spare was repeated at Panter in July 2000 in order to establish whether any changes had occurred during the 4yr that the mirror had been in storage at the OAB, Milan, Italy. The results reported in this paper confirm that the resolution of the JET-X mirrors has remained stable over this storage period.
In an extension of this test program, the flight spare EPIC camera was installed at the focus of the JET-X mirror to simulate the optical system of the Swift XRT. Tolerances in the mirror focal length, the on-axis and off-axis point spread functions were measured and calibration data sets were used to obtain centroid positions of X-ray point sources. The results confirmed Swift's ability to determine the centroid positions of sources at 100mCrab brightness to better than 1arcsec and provided a calibration of the centroiding process as a function of source flux and off-axis angle. The presence of background events in the image frame introduced errors in the centroiding process and this was accounted for by reducing the sampling area used for the centroiding algorithm.
Abbey Anthony F.
Ambrosi Richard M.
Brauninger Heinrich
Burkert Wolfgang
Campana Sergio
No associations
LandOfFree
Point spread function and centroiding accuracy measurements with the JET-X mirror and MOS CCD detector of the Swift gamma ray burst explorer's X-ray telescope does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Point spread function and centroiding accuracy measurements with the JET-X mirror and MOS CCD detector of the Swift gamma ray burst explorer's X-ray telescope, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Point spread function and centroiding accuracy measurements with the JET-X mirror and MOS CCD detector of the Swift gamma ray burst explorer's X-ray telescope will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-933891