Tests of the new AURIGA readout have recently started in the AURIGA ultracryogenic test facility. The most important modifications, with respect to the previous version of the readout, are a new, heavier, resonant capacitive transducer, the tuning of the electrical mode to the two mechanical ones and the use of a low noise two-stage SQUID amplifier. Results regarding the quality factor and the noise of the transducer mechanical and electrical modes are presented.
Bignotto Michele
Bonaldi Michele
Cerdonio Massimo
Falferi Paolo
Marin Andrea
No associations
LandOfFree
Noise measurements and optimization of the high sensitivity capacitive transducer of AURIGA does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Noise measurements and optimization of the high sensitivity capacitive transducer of AURIGA, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Noise measurements and optimization of the high sensitivity capacitive transducer of AURIGA will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-841015