Nuclear Instruments and Methods in Physics Research Section A, Volume 568, Issue 1, p. 141-148.
Physics
3
X- And Gamma-Ray Instruments, X- And Gamma-Ray Spectroscopy, Solid-State Detectors
Scientific paper
A special type of charge-coupled device, the pnCCD, has been developed in the nineties as focal-plane detector for the X-ray astronomy mission XMM-Newton of the European Space Agency. The pnCCD detector has been in operation since the satellite launch in 1999. It is performing up to date spectroscopy of X-rays in combination with imaging and high time resolution. The excellent performance of the flight camera is still maintained; in particular, the energy resolution has been nearly constant since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. The ‘frame store pnCCD’ shows various optimizations in device design and fabrication process. Devices with up to 256×512 pixels have been fabricated in 2004 and recently tested. Simultaneously, a programmable analog signal processor for the readout of the CCD signals, the DUO CAMEX, has been developed. The readout noise of the new detector has a value of 2 electrons ENC which is less than half of the figure of the XMM-Newton pnCCD. We measured an energy resolution that is close to the theoretical limit given by the Fano noise. In particular the low-energy response of the new devices was substantially improved. The quantum efficiency for X-rays is at least 90% in the entire energy band from 0.3 keV up to 11 keV. This is due to the ultra-thin photon entrance window as well as the full depletion of the 450 μm thick back-illuminated pnCCD. The position resolution is better than the pixel sizes of 75 μm×75 μm or 51 μm×51 μm because the signal charge is spread over up to four pixels which allows a more accurate event position determination. ‘Out of time’ events are substantially reduced to the order of 0.1% by operating the pnCCD in frame store mode. Higher operating temperatures, e.g. -20 °C, are possible due to the smaller thermally generated dark-current level of the new devices and the operation at higher frame rates. Low power consumption applications like for the ROSITA X-ray astronomy mission with low frame rates of, e.g. 20 images/s, as well as high frame rate applications, e.g. 200 images/s, are possible with the same device.
Andritschke Robert
Hälker Olaf
Hartmann Robert
Herrmann Sven
Holl Peter
No associations
LandOfFree
Next generation of pnCCDs for X-ray spectroscopy and imaging does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Next generation of pnCCDs for X-ray spectroscopy and imaging, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Next generation of pnCCDs for X-ray spectroscopy and imaging will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1344547