10.1088/0953-2048/17/3/017

A new DTA (Differential Thermal Analysis) device was designed and installed in a Hot Isostatic Pressure (HIP) furnace in order to perform high-pressure thermodynamic investigations up to 2 kbar and 1200C. Thermal analysis can be carried out in inert or oxidising atmosphere up to p(O2) = 400 bar. The calibration of the DTA apparatus under pressure was successfully performed using the melting temperature (Tm) of pure metals (Au, Ag and Al) as standard calibration references. The thermal properties of these metals have been studied under pressure. The values of DV (volume variation between liquid and solid at Tm), ROsm (density of the solid at Tm) and ALPHAm (linear thermal expansion coefficient at Tm) have been extracted. A very good agreement was found with the existing literature and new data were added. This HP-DTA apparatus is very useful for studying the thermodynamics of those systems where one or more volatile elements are present, such as high TC superconducting oxides. DTA measurements have been performed on Bi,Pb(2223) tapes up to 2 kbar under reduced oxygen partial pressure (p(O2) = 0.07 bar). The reaction leading to the formation of the 2223 phase was found to occur at higher temperatures when applying pressure: the reaction DTA peak shifted by 49C at 2 kbar compared to the reaction at 1 bar. This temperature shift is due to the higher stability of the Pb-rich precursor phases under pressure, as the high isostatic pressure prevents Pb from evaporating.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

New apparatus for DTA at 2000 bar: thermodynamic studies on Au, Ag, Al and HTSC oxides does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with New apparatus for DTA at 2000 bar: thermodynamic studies on Au, Ag, Al and HTSC oxides, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and New apparatus for DTA at 2000 bar: thermodynamic studies on Au, Ag, Al and HTSC oxides will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-701366

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.