LEED Holography applied to a complex superstructure: a direct view of the adatom cluster on SiC(111)-(3x3)

Physics – Condensed Matter – Materials Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

11 pages RevTex, 6 figures, Phys. Rev. B in press

Scientific paper

10.1103/PhysRevB.58.10806

For the example of the SiC(111)-(3x3) reconstruction we show that a holographic interpretation of discrete Low Energy Electron Diffraction (LEED) spot intensities arising from ordered, large unit cell superstructures can give direct access to the local geometry of a cluster around an elevated atom, provided there is only one such prominent atom per surface unit cell. By comparing the holographic images obtained from experimental and calculated data we illuminate validity, current limits and possible shortcomings of the method. In particular, we show that periodic vacancies such as cornerholes may inhibit the correct detection of the atomic positions. By contrast, the extra diffraction intensity due to slight substrate reconstructions, as for example buckling, seems to have negligible influence on the images. Due to the spatial information depth of the method the stacking of the cluster can be imaged down to the fourth layer. Finally, it is demonstrated how this structural knowledge of the adcluster geometry can be used to guide the dynamical intensity analysis subsequent to the holographic reconstruction and necessary to retrieve the full unit cell structure.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

LEED Holography applied to a complex superstructure: a direct view of the adatom cluster on SiC(111)-(3x3) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with LEED Holography applied to a complex superstructure: a direct view of the adatom cluster on SiC(111)-(3x3), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and LEED Holography applied to a complex superstructure: a direct view of the adatom cluster on SiC(111)-(3x3) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-7665

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.