High-sensitivity (25-um pitch) microbolometer FPAs

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

3

Scientific paper

RIO has achieved a significant technical breakthrough in uncooled FPAs by reducing the pixel size by a factor of two while maintaining state-of-the-art sensitivity. Raytheon has produced high-quality 320 by 240 micro bolometer FPAs with 25 micrometers pitch pixels. The 320 by 240 FPAs have a sensitivity that is comparable to micro bolometer FPAs with 50 micrometers pixels. The average NETD value for these FPAs is about 35 mK with an f/1 aperture and operating at 30 Hz frame rates. Good pixel operability and excellent image quality have been demonstrated. Pixel operability is greater than 99 percent on some FPAs, and uncorrected responsivity nonuniformity is less than 4 percent. The micro bolometer detectors also have a relatively fast thermal time constant of approximately 10 msec. This state-of-the-art performance has been achieved as a result of an advanced micromachining fabrication process. The process allows maximization of both the thermal isolation and the optical fill-factor. The reduction in pixel size offers several potential benefits for IR systems. For a given system resolution requirement, the 225 micrometers pixels allow a factor of two reduction in both the focal length and aperture size of the sensor optics. The pixel size reduction facilitates a significant FPA cost reduction since the number of die printed on a wafer can be increased. The pixel size reduction has enabled the development of a large-format 640 by 512 FPA array applicable to wide-field-of-view, long range surveillance and targeting missions, and a 160 by 128 array where applications for miniaturization and temperature invariance are required as well as low cost and low power.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

High-sensitivity (25-um pitch) microbolometer FPAs does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with High-sensitivity (25-um pitch) microbolometer FPAs, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High-sensitivity (25-um pitch) microbolometer FPAs will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1187315

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.