Physics – Accelerator Physics
Scientific paper
2009-08-21
Phys.Rev.ST Accel.Beams 13:022803,2010
Physics
Accelerator Physics
10 pages, 6 figures, 2 tables, published version
Scientific paper
10.1103/PhysRevSTAB.13.022803
In order to measure the mass of the eta meson with high accuracy using the d+p -> 3He+eta reaction, the momentum of the circulating deuteron beam in the Cooler Synchrotron COSY of the Forschungszentrum Juelich has to be determined with unprecedented precision. This has been achieved by studying the spin dynamics of the polarized deuteron beam. By depolarizing the beam through the use of an artificially induced spin resonance, it was possible to evaluate its momentum p with a precision of dp/p < 10-4 for a momentum of roughly 3 GeV/c. Different possible sources of error in the application of the spin resonance method are discussed in detail and its possible use during a standard experiment is considered.
Gebel R.
Goslawski P.
Hartmann Markus
Kacharava A.
Khoukaz Alfons
No associations
LandOfFree
High precision beam momentum determination in a synchrotron using a spin resonance method does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with High precision beam momentum determination in a synchrotron using a spin resonance method, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High precision beam momentum determination in a synchrotron using a spin resonance method will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-666595