Errors in Measuring Transverse and Energy Jitter by Beam Position Monitors

Physics – Accelerator Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

30 pages, 6 figures

Scientific paper

The problem of errors, arising due to finite BPM resolution, in the difference orbit parameters, which are found as a least squares fit to the BPM data, is one of the standard and important problems of accelerator physics. Even so for the case of transversely uncoupled motion the covariance matrix of reconstruction errors can be calculated "by hand", the direct usage of obtained solution, as a tool for designing of a "good measurement system", does not look to be fairly straightforward. It seems that a better understanding of the nature of the problem is still desirable. We make a step in this direction introducing dynamic into this problem, which at the first glance seems to be static. We consider a virtual beam consisting of virtual particles obtained as a result of application of reconstruction procedure to "all possible values" of BPM reading errors. This beam propagates along the beam line according to the same rules as any real beam and has all beam dynamical characteristics, such as emittances, energy spread, dispersions, betatron functions and etc. All these values become the properties of the BPM measurement system. One can compare two BPM systems comparing their error emittances and rms error energy spreads, or, for a given measurement system, one can achieve needed balance between coordinate and momentum reconstruction errors by matching the error betatron functions in the point of interest to the desired values.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Errors in Measuring Transverse and Energy Jitter by Beam Position Monitors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Errors in Measuring Transverse and Energy Jitter by Beam Position Monitors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Errors in Measuring Transverse and Energy Jitter by Beam Position Monitors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-373587

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.