Physics – Condensed Matter – Materials Science
Scientific paper
2008-10-18
Physics
Condensed Matter
Materials Science
5 pages, 5 figures
Scientific paper
We show that the static force spectroscopy curve is significantly modified due to presence of intrinsic cantilever instability. This instability acts in tandem with such instabilities like water bridge or molecular bond rupture and makes the static force spectroscopy curve (including "jump-off-contact") dependent on the step-size of the movement of sample stage. A model has been proposed to explain the data. This has been further validated by applying an electric field between tip and substrate which modifies the tip-substrate interaction.
Das Soma
Raychaudhuri A. K.
Sreeram P. A.
No associations
LandOfFree
Effect of intrinsic instability of cantilevers on static mode Atomic Force Spectroscopy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Effect of intrinsic instability of cantilevers on static mode Atomic Force Spectroscopy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Effect of intrinsic instability of cantilevers on static mode Atomic Force Spectroscopy will most certainly appreciate the feedback.