Physics – Instrumentation and Detectors
Scientific paper
2008-01-15
JINST3:P05005,2008
Physics
Instrumentation and Detectors
14 pages, 15 figures. Submitted to JINST
Scientific paper
10.1088/1748-0221/3/05/P05005
The detector for imaging of explosions (DIMEX) is in operation at the synchrotron radiation (SR) beam-line at VEPP-3 electron ring at Budker INP since 2002. DIMEX is based on one-coordinate gas ionization chamber filled with Xe-CO2(3:1) mixture at 7atm, and active Frisch-grid made of Gas Electron Multiplier (GEM). The detector has spatial resolution of ~0.2mm and dynamic range of ~100 that allows to realize the precision of signal measurement at a percent level. The frame rate can be tuned up to 8 MHz (125 ns per image) and up to 32 images can be stored in one shot. At present DIMEX is used with the X-ray beam from 2T wiggler that has ~20 keV average energy. Future possibility to install similar detector at the SR beam-line at VEPP-4 electron ring is discussed.
Aulchenko V. M.
Evdokov O. V.
Shekhtman L. I.
Ten K. A.
Tolochko B. P.
No associations
LandOfFree
Detector for imaging of explosions: present status and future prospects with higher energy X-rays does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Detector for imaging of explosions: present status and future prospects with higher energy X-rays, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Detector for imaging of explosions: present status and future prospects with higher energy X-rays will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-150456