We present a mathematical method for identifying, separating and quantifying the 3D significant distortions. Measurement of a gas quenched C-ring type sample is performed by a Coordinate Measuring Machine (CMM). Quenching simulation is done with the commercial software Forge 2008 TTT. After comparisons, we notice that the distortions and their tendencies are the same but not exactly the amplitudes. We only focus on distortions which have a physical origin, like the pincers opening, often observed in the literature. As a first explanation, we underline the role of phase transformations and volume dilatation of the steel during quenching.
Cyril Nicolas
Cyrille Baudouin
Mihaela Teodorescu
Régis Bigot
Stéphane Leleu
No associations
LandOfFree
Comparison of experimental and simulation distortions of quenched C-ring test parts does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Comparison of experimental and simulation distortions of quenched C-ring test parts, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comparison of experimental and simulation distortions of quenched C-ring test parts will most certainly appreciate the feedback.