Physics – Fluid Dynamics
Scientific paper
2007-10-31
Analytical Chemistry 79, 9240 (2007).
Physics
Fluid Dynamics
Comment on paper by Yamada et al. [Anal. Chem. 76(18), 5465 - 5471 (2004)]. Accepted for Anal. Chem
Scientific paper
10.1021/ac7018816
[First paragraph] In a recent paper Yamada et al. propose the novel concept of "pinched flow fractionation" (PFF) for the continuous size separation and analysis of particles in microfabricated lab-on-a-chip devices. In their description of the basic principle they claim that especially the width of the pinched and broadened segments will affect theseparation performance. In the following we comment on the physics behind this statement.
No associations
LandOfFree
Comment on "Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel" does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Comment on "Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel", we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Comment on "Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel" will most certainly appreciate the feedback.