Physics – Plasma Physics
Scientific paper
Jul 2003
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2003ppcf...45.1167p&link_type=abstract
Plasma Physics and Controlled Fusion, Volume 45, Issue 7, pp. 1167-1182 (2003).
Physics
Plasma Physics
18
Scientific paper
Bolometer diagnostics are installed on the Large Helical Device (LHD) to provide measurements of the total (broad spectrum) electromagnetic radiation emitted by the plasma. Three types of detectors are used: resistive metal film bolometers, absolute extreme ultraviolet photodiodes and infrared imaging video bolometers. Details of the installation in LHD are given for each type of detector. The detector calibration, data analysis and tomography techniques are described and compared and sample results are shown.
Ashikawa N.
Kostrioukov A. Yu
LHD Experiment Group
Liu Ya-Ying
Osakabe M.
No associations
LandOfFree
Bolometer diagnostics for one- and two-dimensional measurements of radiated power on the Large Helical Device does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Bolometer diagnostics for one- and two-dimensional measurements of radiated power on the Large Helical Device, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Bolometer diagnostics for one- and two-dimensional measurements of radiated power on the Large Helical Device will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1885294