Calorimetric measurements of AC loss and hence interstrand contact resistance (ICR), were measured on three samples of Rutherford cable wound with Cu-stabilized jelly-roll type unplated Nb3Al strand. One of the cable types was furnished with a thin core of AISI 316L stainless steel and the other two were both uncored but insulated in different ways. The cables were subjected to a room-temperature-applied uniaxial pressure of 12 MPa that was maintained during the reaction heat treatment (RHT), then vacuum impregnated with CTD 101 epoxy, and repressurized to 100 MPa during AC-loss measurement. The measurements were performed at 4.2 K in a sinusoidal field of amplitude 400 mT at frequencies of 1 to 90 mHz (no DC-bias field) that was applied both perpendicular and parallel to the face of the cable (the face-on, FO, and edge-on, EO, directions, respectively). For the cored cable the FO-measured effective ICR (FO-ICR), was 5.27 . Those for the uncored cables were less than 0.08 . As shown previously for NbTi- and Nb3Sn-based Rutherford cables, the FO-ICR can be significantly increased by the insertion of a core, although in this case it is still below the range recommended for accelerator-magnet use. Post-measurement dissection of one of the cables showed that the impregnating resin had permeated between the strands and coated the core with a thin, insulating layer excepting for some sintered points of contact. In the uncored cables the strands were coated with resin except for the points of interstrand contact. It is suggested that in the latter case this tendency for partial coating leads to a processing-sensitive FO-ICR.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

AC Loss and Contact Resistance In Copper-Stabilized Nb3Al Rutherford Cables with and without a Stainless Steel Core does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with AC Loss and Contact Resistance In Copper-Stabilized Nb3Al Rutherford Cables with and without a Stainless Steel Core, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and AC Loss and Contact Resistance In Copper-Stabilized Nb3Al Rutherford Cables with and without a Stainless Steel Core will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-196040

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.