Absolute specific heat measurements of a microgram Pb crystal using ac nanocalorimetry

Physics – Condensed Matter – Superconductivity

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Submitted as a conference paper to LT26

Scientific paper

Heat capacity measurements using the ac steady state method are often considered difficult to provide absolute accuracy. By adjusting the working frequency to maintain a constant phase and using the phase information to obtain the heat capacity, we have found that it is possible to achieve good absolute accuracy. Here we present a thermodynamic study of a ~ 2.6 {\mu}g Pb superconducting crystal to demonstrate the newly opened capabilities. The sample is measured using a differential membrane-based calorimeter. The custom-made calorimetric cell is a pile of thin film Ti heater, insulation layer and Ge_{1-x}Au_{x} thermometer fabricated in the center of two Si_{3}N_{4} membranes. It has a background heat capacity < 100 nJ/K at 300K, decreasing to 9 pJ/K at 1 K. The sample is characterized at temperatures down to 0.5 K. The zero field transition at Tc = 7.21 K has a width \approx 20 mK and displays no upturn in C. From the heat capacity jump at Tc and the extrapolated Sommerfeld term we find \DeltaC/{\gamma}Tc = 2.68. The latent heat curve obtained from the zero field heat capacity measurement, and the deviations of the thermodynamic critical field from the empirical expression Hc =Hc(0)[1-(T/Tc)^2] are discussed. Both analyses give results in good agreement with literature.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Absolute specific heat measurements of a microgram Pb crystal using ac nanocalorimetry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Absolute specific heat measurements of a microgram Pb crystal using ac nanocalorimetry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Absolute specific heat measurements of a microgram Pb crystal using ac nanocalorimetry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-302175

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.