A new CTE Correction Algorithm forPoint Source Spectroscopy with theSTIS CCD:Correcting for charge trap filling by the Ôred haloÕ of theCCD Point Spread Function redward of 8000 A¡

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Hubble Space Telescope, Hst, Space Telescope Science Institute, Stis

Scientific paper

The CTE-related loss for spectrophotometry of point sources with the STIS CCD is parametrized in terms of dependencies on the signal level of the source spectrum within the extraction box, the background level, and the signal in the point spread function located between the standard extraction box and the read-out amplifier. Primary constraints on the CTE correction algorithm are provided by estimates of CTE losses usingCCD spectra of spectrophotometric standard stars. For point-source spectra taken at the standard reference position at the center of the detector, the algorithm corrects CTElosses as large as 30% to within ˜1.5% RMS throughout the wavelength range coveredby the first-order CCD modes. This uncertainty is similar to the Poisson noise associated with a resolution element of a spectrum with an extracted signal level of about 2500 electrons per pixel. The results described here supersede those reported in an earlier STIS Instrument Science Report (ISR 2003-03).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

A new CTE Correction Algorithm forPoint Source Spectroscopy with theSTIS CCD:Correcting for charge trap filling by the Ôred haloÕ of theCCD Point Spread Function redward of 8000 A¡ does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with A new CTE Correction Algorithm forPoint Source Spectroscopy with theSTIS CCD:Correcting for charge trap filling by the Ôred haloÕ of theCCD Point Spread Function redward of 8000 A¡, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A new CTE Correction Algorithm forPoint Source Spectroscopy with theSTIS CCD:Correcting for charge trap filling by the Ôred haloÕ of theCCD Point Spread Function redward of 8000 A¡ will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1329695

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.