The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and a scintillator based multiplicity-trigger counter during the first run of this experiment in 1994. We obtained a time resolution of 78 ps for the beam counter at an incident beam rate 5 x 10^5 Hz and 100 ps at a rate of 1 x 10^7 Hz. Pulse height discrimination is used to obtain a minimum bias and a 10% centrality trigger from the multiplicity detectors. The multiplicity counter has a time resolution of 250 ps.
Barish Kenneth
Buren Van G.
Haridas P.
Majka R. D.
Pless I. A.
No associations
LandOfFree
A 10 MHz beam counter and a multiplicity detector for the E864 spectrometer does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with A 10 MHz beam counter and a multiplicity detector for the E864 spectrometer, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and A 10 MHz beam counter and a multiplicity detector for the E864 spectrometer will most certainly appreciate the feedback.