Total Differential Errors in One-Port Network Analyzer Measurements with Application to Antenna Impedance

Physics – Classical Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

8 pages, 13 figures

Scientific paper

The objective was to study uncertainty in antenna input impedance resulting from full one-port Vector Network Analyzer (VNA) measurements. The VNA process equation in the reflection coefficient p of a load, its measurement m and three errors Es -determinable from three standard loads and their measurements- was considered. Differentials were selected to represent measurement inaccuracies and load uncertainties (Differential Errors). The differential operator was applied on the process equation and the total differential error dp for any unknown load (Device Under Test DUT) was expressed in terms of dEs and dm, without any simplification. Consequently, the differential error of input impedance Z -or any other physical quantity differentiably dependent on p- is expressible. Furthermore, to express precisely a comparison relation between complex differential errors, the geometric Differential Error Region and its Differential Error Intervals were defined. Practical results are presented for an indoor UHF ground-plane antenna in contrast with a common 50 Ohm DC resistor inside an aluminum box. These two built, unshielded and shielded, DUTs were tested against frequency under different system configurations and measurement considerations. Intermediate results for Es and dEs characterize the measurement system itself. A number of calculations and illustrations demonstrate the application of the method.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Total Differential Errors in One-Port Network Analyzer Measurements with Application to Antenna Impedance does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Total Differential Errors in One-Port Network Analyzer Measurements with Application to Antenna Impedance, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Total Differential Errors in One-Port Network Analyzer Measurements with Application to Antenna Impedance will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-382935

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.