Physics – Condensed Matter
Scientific paper
May 1996
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1996aipc..370.1029b&link_type=abstract
Proceedings of the conference of the American Physical Society topical group on shock compression of condensed matter. AIP Conf
Physics
Condensed Matter
High-Pressure Apparatus, Shock Tubes, Diamond Anvil Cells, High-Pressure And Shock Wave Effects In Solids And Liquids, X- And Gamma-Ray Sources, Mirrors, Gratings, And Detectors, X-Ray Effects
Scientific paper
This paper describes recent work to improve the measurement of the stress response of materials to intense, short pulses of radiation. When Saturn fires, large prompt electrical noise pulses are induced in stress measurement circuits. The conventional wisdom has been that the shorted guard ring quartz gauge was the only configuration with acceptable prompt signal-to-noise characteristics for stress measurements in this pulsed radiation environment. However, because of abnormal signal distortion, the shorted guard ring gauge is restricted to a maximum stress of about 8 kbars. Below this level, the normal, quantified signal distortion is correctable with analytical deconvolution techniques. The shunted guard ring gauge is acceptable for high fidelity measurements to about 25 kbars with negligible signal distortion. Experiments were conducted on the Saturn soft x-ray source which show that higher fidelity shunted guard ring gauges can successfully measure stress with acceptable induced noise. We also found that a 50-ohm impedance matching resistor at the gauge reduced the prompt noise amplitude and improved the baseline quality of the measurement prior to shock wave arrival.
Barrett W. H.
de La Cruz C. F.
Greenwoll J. I.
Johnson David E.
Smith Walter C.
No associations
LandOfFree
Noise measurements in shunted, shorted, and fully electroded quartz gauges in the saturn plasma radiation source x-ray simulator does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Noise measurements in shunted, shorted, and fully electroded quartz gauges in the saturn plasma radiation source x-ray simulator, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Noise measurements in shunted, shorted, and fully electroded quartz gauges in the saturn plasma radiation source x-ray simulator will most certainly appreciate the feedback.