In this paper we describe the operation and performance of the HERA-B Outer Tracker, a 112674 channel system of planar drift tube layers. The performance of the HERA-B Outer Tracker system fullfilled all requirements for stable and efficient operation in a hadronic environment, thus confirming the adequacy of the honeycomb drift tube technology and of the front-end readout system. The detector was stably operated with a gas gain of 30000 in an Ar/CF4/CO2 (65:30:5) gas mixture, yielding a good efficiency for triggering and track reconstruction, larger than 95 % for tracks with momenta above 5 GeV/c. The hit resolution of the drift cells was 300 to 320 micrometers and the relative momentum resolution can be described as: sigma(p)/p (in %) = (1.61 +- 0.02) + (0.0051 +- 0.0006) p. At the end of the HERA-B running no aging effects in the Outer Tracker cells were observed.
No associations
LandOfFree
The Outer Tracker Detector of the HERA-B Experiment. Part III: Operation and Performance does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with The Outer Tracker Detector of the HERA-B Experiment. Part III: Operation and Performance, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The Outer Tracker Detector of the HERA-B Experiment. Part III: Operation and Performance will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-448292