Design and Performance of the Level 1 Calorimeter Trigger for the BABAR Detector

Physics – High Energy Physics – High Energy Physics - Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

IEEE TNS paper, 10 figures

Scientific paper

10.1109/23.940115

Since May 1999 the BABAR detector has been taking data at the PEP-II asymmetric electron-positron collider at the Stanford Linear Accelerator Center, California. This experiment requires a very large data sample and the PEP-II accelerator uses intense beams to deliver the high collision rates needed. This poses a severe challenge to the BaBar trigger system, which must reject the large rate of background signals resulting from the high beam currents whilst accepting the collisions of interest with very high efficiency. One of the systems that performs this task is the Level 1 Calorimeter Trigger, which identifies energy deposits left by particles in the BABAR calorimeter. It is a digital, custom, fixed latency system which makes heavy use of high-speed FPGA devices to allow flexibility in the choice of data filtering algorithms. Results from several intermediate processing stages are read out, allowing the selection algorithm to be fully analysed and optimized offline. In addition, the trigger is monitored in real time by sampling these data and cross-checking each stage of the trigger calculation against a software model. The design, implementation, construction and performance of the Level 1 Calorimeter Trigger during the first year of BABAR operation are presented.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Design and Performance of the Level 1 Calorimeter Trigger for the BABAR Detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Design and Performance of the Level 1 Calorimeter Trigger for the BABAR Detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Design and Performance of the Level 1 Calorimeter Trigger for the BABAR Detector will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-227032

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.