Physics
Scientific paper
Feb 2002
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2002aipc..605..161a&link_type=abstract
LOW TEMPERATURE DETECTORS: Ninth International Workshop on Low Temperature Detectors. AIP Conference Proceedings, Volume 605, p
Physics
3
Superconducting Optical, X-Ray, And Gamma-Ray Detectors, X- And Gamma-Ray Sources, Mirrors, Gratings, And Detectors
Scientific paper
Tunnel junctions Al(0)/Nb/Al(1)/AlOx/Al(2)/Nb/NbN with bottom
electrode Al(0)/Nb/Al(1) as a killed electrode were studied at
temperatures 1.35 and 0.3 K. It was found that at T=0.3 K tunneling from
the killed electrode, absent at T=1.35 K, appeared. It increases the
detector signal and broadens the spectrum. .
Andrianov V. A.
Dmitriev Pavel N.
Koshelets Valery. P.
Kozin M. G.
Romashkina I. L.
No associations