Physics
Scientific paper
May 1992
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1992htpd.conf...15h&link_type=abstract
Presented at the 9th Topical Conference on High-Temperature Plasma Diagnostics, Santa Fe, NM, 15-19 Mar. 1992
Physics
Image Processing, Imaging Techniques, Laser Plasmas, Photons, Plasma Diagnostics, Radiation Detectors, Streak Cameras, X Ray Imagery, X Ray Sources, X Rays
Scientific paper
We have developed a diagnostic suitable for high photon energy (approximately 7 kev) time resolved one dimensional x-ray imaging on Nova. This diagnostic uses a 15 micron wide, 750 micron long imaging slit mounted on a 20X magnification snout which is coupled to an x-ray streak camera of variable streak speed. This diagnostic fits into retractable manipulators on the 10-beam chamber at Nova. In situ backlit grid experiments using a large-area backlighter give a spatial resolution FWHM of about 17 micron with high brightness.
Hammel Bruce A.
Landen Otto L.
Pasha R. A.
Remington Bruce A.
No associations
LandOfFree
High energy x ray imaging diagnostic on Nova does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with High energy x ray imaging diagnostic on Nova, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High energy x ray imaging diagnostic on Nova will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1517189