Physics
Scientific paper
Jun 1994
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1994spie.2219..338d&link_type=abstract
Proc. SPIE Vol. 2219, p. 338-344, Cockpit Displays, Darrel G. Hopper; Ed.
Physics
Scientific paper
An efficient, high intensity, mercury free cathode luminescent lamp/power supply assembly has been designed for use in the backlighting of AMLCD's. It has demonstrated excellent spectral stability over the temperature range of - 55 to 70 degrees C and its dimming range of 1 to 10,000 Ft-L. The CLL has a projected useful life of 10,000 hours. A life test sample currently has 5,000 hours with a decrease of 16% from its' initial level.
Dunbar Thomas
Whitson Walter J.
No associations
LandOfFree
Cathodoluminescent lamp for LCD backlighting does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Cathodoluminescent lamp for LCD backlighting, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Cathodoluminescent lamp for LCD backlighting will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1509616