Using data taken during WFC3's Thermal Vacuum 3 (TV3) testing campaign, we have characterized the dark current behavior in the IR Channel, which contained IR-4 (FPA165). The Contract End Item (CEI) Specifications call for dark current to be below 0.4 e-/sec/pixel, with a goal of 0.1 e-/sec/pixel. We measure dark current values well below the spec and goal values. The longest exposure time ramps show dark current values in the 0.045 - 0.060 e-/sec/pixel range. Initial dark current calibration files will be created from these TV3 data.