Physics – Optics
Scientific paper
Jul 2000
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2000spie.4012..137i&link_type=abstract
Proc. SPIE Vol. 4012, p. 137-144, X-Ray Optics, Instruments, and Missions III, Joachim E. Truemper; Bernd Aschenbach; Eds.
Physics
Optics
Scientific paper
We present the detailed study of the response function of X- ray CCD cameras (XIS; X-ray Imaging Spectrometer). A pulse height distribution for monochromatic X-rays show a low- energy tail component and several weak lines in addition to main peak corresponding to incident X-ray energy. We divided the response function into six components; main peak, sub peak, triangle component, constant component, Si escape, and Si line. Each of them represents different physical processes in the CCD. We did the data fitting, numerical calculations, and Monte Carlo simulations to study energy dependence of the shape and intensity of these components, and made the response function as a function of X-ray energy.
Awaki Hisamitsu
Hamaguchi Kenji
Imanishi Kensuke
Koyama Katsuji
Murakami Hiroshi
No associations
LandOfFree
High-energy performance of x-ray imaging spectrometers on board Astro-E does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with High-energy performance of x-ray imaging spectrometers on board Astro-E, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High-energy performance of x-ray imaging spectrometers on board Astro-E will most certainly appreciate the feedback.