Ion Etching of Dental Tissues in a Scanning Electron Microscope

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

TOOTH sections have been bombarded with a 5-kV argon ion beam inside the specimen chamber of a scanning electron microscope. This apparatus was designed so that the ion beam could be focused into a 1.5-mm diameter spot on the surface of the specimen, covering the area viewed by the microscope. The ions were extracted from a radio-frequency ion source and were focused by two electrostatic lenses on to the specimen, through two apertures. The pressure in the specimen chamber when the ion source was running was better than 10-6 mm mercury. The ion beam density was not uniform over its cross-section, but varied from about 10 m. amp/cm2 at the centre to zero at the edge; this enabled us to check that, for the current densities we utilized, the nature of the changes in the specimen surface that was produced was not a function of the rate of etching. The bombarded area was kept to a minimum to reduce the amount of material deposited on the electron collection system, and reduce the temperature rise, which we have calculated to be less than 100° C, using the values of thermal conductivity given by Craig and Peyton1. The total ion current was kept to about 15µ amp. The micrographs were taken with a 16-kV scanning electron beam and only the high-energy reflected electrons were used to form the picture. This allowed micrographs to be taken with a resolution better than 500 Å., even though the specimen tended to charge under the electron beam. This method of observation also allows pictures to be taken while the surface is under bombardment; but for this work it was found preferable alternately to bombard for, say, 5 min, and then observe the surface at leisure. The ion beam made an angle of about 40° to the specimen normal: the direction is indicated by the arrow on the micrographs. The surface was also viewed at an oblique angle, as is indicated by the magnification symbols on the micrographs (Figs. 1 and 2).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Ion Etching of Dental Tissues in a Scanning Electron Microscope does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Ion Etching of Dental Tissues in a Scanning Electron Microscope, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Ion Etching of Dental Tissues in a Scanning Electron Microscope will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1331180

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.