Particle extinction measured at ambient conditions with differential optical absorption spectroscopy. 1. System setup and characterization

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Scientific paper

We describe an instrument for measuring the particle extinction coefficient at ambient conditions in the spectral range from 270 to 1000 nm. It is based on a differential optical absorption spectroscopy (DOAS) system, which was originally used for measuring trace-gas concentrations of atmospheric absorbers in the ultraviolet-visible wavelength range. One obtains the particle extinction spectrum by measuring the total atmospheric extinction and subtracting trace-gas absorption and Rayleigh scattering. The instrument consists of two nested Newton-type telescopes, which are simultaneously used for emitting and detecting light, and two arrays of retroreflectors at the ends of the two light paths. The design of this new instrument solves crucial problems usually encountered in the design of such instruments. The telescope is actively repositioned during the measurement cycle. Particle extinction is simultaneously measured at several wavelengths by the use of two grating spectrometers. Optical turbulence causes lateral movement of the spot of light in the receiver telescope. Monitoring of the return signals with a diode permits correction for this effect. Phase-sensitive detection efficiently suppresses background signals from the atmosphere as well as from the instrument itself. The performance of the instrument was tested during a measurement period of 3 months from January to March 2000. The instrument ran without significant interruption during that period. A mean accuracy of 0.032 km^-1 was found for the extinction coefficient for an 11-day period in March.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Particle extinction measured at ambient conditions with differential optical absorption spectroscopy. 1. System setup and characterization does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Particle extinction measured at ambient conditions with differential optical absorption spectroscopy. 1. System setup and characterization, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Particle extinction measured at ambient conditions with differential optical absorption spectroscopy. 1. System setup and characterization will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1214278

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.