Titan's Near-Infrared Imaging with Adaptive Optics

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Titan's images have been acquired since 1993 with the ADONIS adaptive optics system installed at the ESO telescope in La Silla (Chile). The near-infrared range 1-2.5 mu m was covered in the centers and the wings of the methane atmospheric windows at 1.3, 1.6 and 2.0 micron with narrow-band filters and CVF. The low Strehl ratio in the J-band images has prevented their analysis up to now, but the H- and K-band images are diffraction-limited and allow to resolve Titan's disk. The associated Point Spread Functions have very high signal-to-noise. We have corrected for systematic and center-to-limb effects and applied deconvolution processes to our data. The contrast on the reduced images is about 30%. Both the leading and the trailing hemispheres of Titan have been observed. The 2-mu m images show a broad equatorial bright region on Titan's leading hemisphere near 114 degrees LCM, in accordance with HST results (Smith et al., 1996, Icarus 119, 336) and spectroscopic measurements (Coustenis et al., 1995, Icarus 118, 87). High-quality flat-fielding of our data has allowed us to resolve this region into several (2 or 3) distinct areas (Combes et al., 1997, Icarus, in press). The trailing hemisphere of Titan is not completely dark, but shows bright zones near the poles, with a pronounced North-South asymmetry. The high-northern latitudes are uniformly brighter at 2.0 mu m than the equatorial and southern ones. We will present new images of Titan taken near 1.6 micron (H band) with narrow-band filters and CVF, that set stringent contraints on the nature of the satellite's surface.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Titan's Near-Infrared Imaging with Adaptive Optics does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Titan's Near-Infrared Imaging with Adaptive Optics, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Titan's Near-Infrared Imaging with Adaptive Optics will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1190000

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.