Fast Plasma Instrument for MMS: Simulation Results

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2723 Magnetic Reconnection (7526, 7835), 7526 Magnetic Reconnection (2723, 7835), 7835 Magnetic Reconnection (2723, 7526)

Scientific paper

Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. The Dual Electron Spectrometer (DES) of the Fast Plasma Instrument (FPI) for MMS meets these demanding requirements by acquiring the electron velocity distribution functions (VDF's) for the full sky with high-resolution angular measurements every 30 ms. This will provide unprecedented access to electron scale dynamics within the reconnection diffusion region. The DES consists of eight half-top-hat energy analyzers. Each analyzer has a 6° × 180° field of view (FOV) with a single pixel resolution of 6° × 11.25°. Full-sky coverage is achieved by electrostatically stepping the FOV of each of the eight sensors through four discrete deflection look directions. Data compression and burst memory management will provide approximately 30 minutes of high time resolution data during each orbit of the four MMS spacecraft. Each spacecraft will intelligently downlink the data sequences that contain the greatest amount of temporal structure. Here we present the results of a simulation of the DES analyzer measurements, data compression and decompression, as well as ground- based analysis using as a seed re-processed Cluster/PEACE electron measurements. The Cluster/PEACE electron measurements have been re-processed through virtual DES analyzers with their proper geometrical, energy, and timing scale factors and re-mapped via interpolation to the DES angular and energy phase- space sampling measurements. The results of the simulated DES measurements are analyzed and the full moments of the simulated VDF's are compared with those obtained from the Cluster/PEACE spectrometer using a standard quadrature moment, a newly implemented spectral spherical harmonic method, and a singular value decomposition method. Our preliminary moment calculations show a remarkable agreement within the uncertainties of the measurements, with the results obtained by the Cluster/PEACE electron spectrometers. The data analyzed was selected because it represented a potential reconnection event as currently published.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Fast Plasma Instrument for MMS: Simulation Results does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Fast Plasma Instrument for MMS: Simulation Results, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Fast Plasma Instrument for MMS: Simulation Results will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1095468

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.