Physics – Optics
Scientific paper
May 2008
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2008spie.6959e...9k&link_type=abstract
Micro (MEMS) and Nanotechnologies for Space, Defense, and Security II. Edited by George, Thomas; Cheng, Zhongyang. Proceedings
Physics
Optics
Scientific paper
We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (< 1000 cm3) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions > 600 at sensitivity levels on the order of 10-3 cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions ~1000, though at the expense of sensitivity and instrument volume.
Brinckerhoff William B.
Getty Stephanie A.
Herrero Federico A.
Jones Hollis H.
Kahle Duncan M.
No associations
LandOfFree
Simulation of a miniature, low-power time-of-flight mass spectrometer for in situ analysis of planetary atmospheres does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Simulation of a miniature, low-power time-of-flight mass spectrometer for in situ analysis of planetary atmospheres, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Simulation of a miniature, low-power time-of-flight mass spectrometer for in situ analysis of planetary atmospheres will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1077466