X-Ray Micro-Calorimeter Based on Si Thermistors for X-Ray Astronomy: Design and First Measurements

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Scientific paper

X-ray Astronomy provides a unique window on a wide variety of astrophysical phenomena. The currently operating X-ray space observatories perform X-ray spectral imaging with the use of CCDs. When available, cryogenic X-ray microcalorimeter arrays will far outperform CCDs in terms of spectral resolution, energy bandwidth and count rate. Experience has been gained with Infra-Red bolometer arrays at CEA-LETI (Grenoble) in collaboration with the CEA-SAp (Saclay); taking advantage of this background, we are now developing an X-ray spectro-imaging camera for the next generation space astronomy missions, using silicon technology (implanted and high temperature diffused thermistors). Each pixel of this array detector is made of a tantalum absorber bound, by indium bump hybridization, to a silicon thermistor. The absorber array is bound to the thermistor array in a single automatic step. The thermo-mechanical link, provided by hybridization, is being improved in terms of thermal capacitance. Finally, our main effort is in developing arrays of silicon thermistors with negligible excess 1/ f noise. The thermistor has been simulated with the 2D simulator ATHENA (SILVACO International). We studied the effects of the implants and their thermal treatment on both vertical and lateral dopant distributions at the edges of the thermistor. Prototypes have been created following the procedure optimized by the ATHENA simulation. We present the status of the development and results of measurements performed on these four main building blocks required to create a detector array up to 32×32 pixels in size.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

X-Ray Micro-Calorimeter Based on Si Thermistors for X-Ray Astronomy: Design and First Measurements does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with X-Ray Micro-Calorimeter Based on Si Thermistors for X-Ray Astronomy: Design and First Measurements, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and X-Ray Micro-Calorimeter Based on Si Thermistors for X-Ray Astronomy: Design and First Measurements will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1704708

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.