Details

Clean Rooms, Contamination, Hubble Space Telescope, Microbalances, Mirrors, Quartz Crystals, Space Environment Simulation, Temperature Effects, Acoustic Propagation, Cameras, Gas Detectors, Installing, Optical Equipment, Outgassing, Real Time Operation, Residues

Scientific paper

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-949719

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.