Experimental data shows anomalously large Ultra Cold Neutrons (UCN) reflection losses and that the process of UCN reflection is not completely coherent. UCN anomalous losses under reflection cannot be explained in the context of neutron optics calculations. UCN losses by means of incoherent scattering on material defects are considered and cross-section values calculated. The UCN capture cross-section on material defects is enhanced by a factor of 10^4 due to localization of UCN around defects. This phenomenon can explain anomalous losses of UCN.
Fomin Andrei
Kharitonov A. A.
Krasnoshekova I.
Lasakov M.
Romanenko Nikolai
No associations
LandOfFree
UCN anomalous losses and the UCN capture cross-section on material defects does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with UCN anomalous losses and the UCN capture cross-section on material defects, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and UCN anomalous losses and the UCN capture cross-section on material defects will most certainly appreciate the feedback.