Total ionizing dose and proton radiation characterization of Si P-i-N visible hybrid focal plane arrays

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The results of total ionizing dose and proton fluence characterization of hybrid Si P-i-N focal plane arrays are reported. The focal plane arrays consist of a silicon P-i-N detector array bump bonded to 128 x 128 CMOS readout integrated circuit (ROIC). The FPAs were characterized in total ionizing dose and proton fluence radiation environments. Full radiometric characterizations were performed at each radiation dose level to determine the impact of the radiation on dark current, noise, responsivity, sensitivity, and dynamic range. Results from the total ionizing dose experiment demonstrate an unexpected increase in the visible P-i-N detector dark current. The median dark current increased more than two orders of magnitude from pre-radiation to 300 krad(Si) and the magnitude of the dark current was found to be a strong function of detector bias. No appreciable change in responsivity or noise was observed for wavelengths above 400 nm up to a total ionizing dose of 750 krad(Si). Results from the proton radiation experiment show no appreciable change in responsivity was observed up to a 63 MeV proton fluence of 3 x 1012 protons/cm2 (400 krad(Si) of total ionizing dose). The median dark current increased approximately two orders of magnitude, but even at this higher level, the dark current did not contribute significantly to the median noise at an integration time of 10 ms. The dominant degradation mechanism, in both the total ionizing dose and proton fluence environments, is an increase in dark current in the Si P-i-N detectors.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Total ionizing dose and proton radiation characterization of Si P-i-N visible hybrid focal plane arrays does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Total ionizing dose and proton radiation characterization of Si P-i-N visible hybrid focal plane arrays, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Total ionizing dose and proton radiation characterization of Si P-i-N visible hybrid focal plane arrays will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-802020

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.