THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

15 pages, 11 figures, MPGD2011 conference proceeding

Scientific paper

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-549164

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.