The low-temperature energy calibration system for the CUORE bolometer array

Physics – Nuclear Physics – Nuclear Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

To be published in the proceedings of the 13th International Workshop on Low Temperature Detectors (LTD), Stanford, CA, July 2

Scientific paper

10.1063/1.3292432

The CUORE experiment will search for neutrinoless double beta decay (0nDBD) of 130Te using an array of 988 TeO_2 bolometers operated at 10 mK in the Laboratori Nazionali del Gran Sasso (Italy). The detector is housed in a large cryogen-free cryostat cooled by pulse tubes and a high-power dilution refrigerator. The TeO_2 bolometers measure the event energies, and a precise and reliable energy calibration is critical for the successful identification of candidate 0nDBD and background events. The detector calibration system under development is based on the insertion of 12 gamma-sources that are able to move under their own weight through a set of guide tubes that route them from deployment boxes on the 300K flange down into position in the detector region inside the cryostat. The CUORE experiment poses stringent requirements on the maximum heat load on the cryostat, material radiopurity, contamination risk and the ability to fully retract the sources during normal data taking. Together with the integration into a unique cryostat, this requires careful design and unconventional solutions. We present the design, challenges, and expected performance of this low-temperature energy calibration system.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The low-temperature energy calibration system for the CUORE bolometer array does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The low-temperature energy calibration system for the CUORE bolometer array, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The low-temperature energy calibration system for the CUORE bolometer array will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-453226

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.