The LINC-NIRVANA fringe and flexure tracker: cryo-ambient mechanical design

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The correction of atmospheric differential piston and instrumental flexure effects is mandatory for interferometric operation of the LBT NIR interferometric imaging camera LINC-NIRVANA. The task of the Fringe and Flexure Tracking System (FFTS) is to detect and correct these effects in a real-time closed loop. Being a Fizeau-Interferometer, the LBT provides a large field of view (FoV). The FFTS can make use of the large FoV and increase the sky coverage of the overall instrument if it is able to acquire the light of a suitable fringe tracking reference star within the FoV. For this purpose, the FFTS detector needs to be moved to the position of the reference star PSF in the curved focal plane and needs to precisely follow its trajectory as the field rotates. Sub-pixel (1 pixel = 18.5 micron) positioning accuracy is required over a travel range of 200mm x 300mm x 70mm. Strong are the constraints imposed by the need of a cryogenic environment for the moving detector. We present a mechanical design, in which the Detector Positioning Unit (DPU) is realized with off-the-shelf micro-positioning stages, which can be kept at ambient temperature. A moving baffle will prevent the intrusion of radiation from the ambient temperature environment into the cryogenic interior of the camera. This baffle consists of two nested disks, which synchronously follow any derotation - or repositioning trajectory of the DPU. The detector, its fanout board and a filter wheel are integrated into a housing that is mounted on top of the DPU and that protects the FFTS detector from stray light. Long and flexible copper bands allow heat transfer from the housing to the LINC-NIRVANA heat exchanger.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The LINC-NIRVANA fringe and flexure tracker: cryo-ambient mechanical design does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The LINC-NIRVANA fringe and flexure tracker: cryo-ambient mechanical design, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The LINC-NIRVANA fringe and flexure tracker: cryo-ambient mechanical design will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1623640

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.